Medical hospital equipment Multi-parameter patient monitor YSF9


 
Features
 

Core
· Newly advanced A9 main board with Linux OS, calculating speed is 4 times faster than traditional products
 
· Support storage of 2160 hours trend table and graph review, 2 hours waveform review,
2000 groups NIBP review and 2000 alarm events review
 
Body
· 15 inch high-brightness TFT LED
· Support display 9~13 waveforms
· Support 7 channel ECG waveform display simultaneously  
· Optional HDMI output
 
Printer
· Built-in high-speed 50mm thermal printer
 (Brand: SEIKO, Japan)
 
Central System
· Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station.
· Optional Support HL7 (Health Level Seven)
 
 
Alarm
· Double high light alarm light bar.
· Three-level acousto-optic alarm
· Sensor-off alarm
· Paper out alarm
· Support alarm review
· Support alarm pause
 
Linux OS
· Support operation with mouse and computer keyboard (option)
 
· Multi-display mode to meet different clinical requirement, including standard interface, big font, OxyCRG, trend graph, NIBP review and full leads ECG interface.
 
· NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
· Generate ID automatically when register a new patient
· Support medical history search by patient ID, name and mobile number
· 18 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
· Drug calculation and titration table 
· Support multi-language display
· Support online software upgrading by net/USB

Interface
Transducer socket
· ECG
· SPO2
· NIBP  
· IBP 1 / IBP 2
· TEMP 1
· TEMP 2 / Mainstream EtCO2 / AG (multi-gas)
· Sidestream EtCO2
 
LAN / Central monitor system interface
· The LAN port is for connecting the monitor to a central monitor system network.
 
Input device interface
· This optional interface provides an USB ports to enable the monitor to be connected to off-the-shelf input devices:
· Mouse: any specified trackball or USB mouse may be used for navigation and data entry.
· Computer keyboard: an USB computer keyboard can be used for data entry instead of the on-screen pop-up keyboard.
[Remark: user has to restart the machine after plug and unplug the mouse / computer keyboard.]
 
· Knob (Standard)
 
 
Service Features
· The Support Tool helps technical personnel to
–  carry out configuration, upgrades and troubleshooting on an individual monitor.
– back up the monitor settings.
 
· The Service Mode is password-protected and ensures that only trained staff can access service tests and tasks. It includes Skin Type, Brightness Setting, Clear Data and NIBP Calibration.
· The Support Tool uses the USB interface of the monitor for software upgrading.

Performance Specifications
 
Dimension and Weight
- Dimension: 393mm*382mm*173mm
- Weight: 4.5kg(excluding accessories)
 
Power Supply
- Voltage: AC100~240V, 50/60HZ, Power≤60W
 
Display
- 15" color TFT LED  
- Resolution: 1024*768 pixels
 
Battery (Pluggable)
- Type: Rechargeable lithium battery 14.8V/2200mAh
- Charge Cycle: ≥500 times
- Working time: 2 hours (optional larger battery for 4-5 hours)
 
Recorder (Option)
- Method: Thermal printer
- Paper width: 50 mm (1.97 in)
- Printing speed: 12.5/ 25/ 50 mm/s
- Trace: Max. 3 tracks
- Recording way: Real-time Recording, Review Printing,  
   Periodic Recording, Alarm Recording
 
Alarm
- Level: Low, medium and high
- Indication: Auditory and visual
- Alarm volume adjustable
- Alarm pause time: 1min, 2min
- Parameter alarm type: Latch/ Unlatch
 
Input Device
- Knob (Standard)
- Keypad input (Standard)
- Mouse/ Keyboard input (option)
 
System Output & Extensible Interface
- Ethernet Network: 1 standard RJ45 socket
- USB Port: 1
- Video Output:  1 HDMI port (option)
 
Operating Environment
- Temperature:  5 ~ 40 ℃
- Humidity:  15% ~ 80% (non-condensing)
- Atmosphere pressure:  86 KPa ~ 110 KPa
 
 
 
 
Transportation and Storage Environment
- Temperature:  -20~50 ℃
- Humidity:  10%~90%  (non-condensing)
- Atmosphere pressure:  86 KPa ~ 110 KPa
 
Safety
- IEC60601-1 Approved, CE marking according to MDD93/42/EEC
- With reference to RoHS Directive 2011/65/EU recasting
 
Trend & Reviewing
- Trend: 2160 hours
- ARR events: 128 groups of ARR events and associated waveform
- NIBP measurement reviewing: 2000 groups
- Waveform review: 2 hours
- Alarm event: 2000 groups of parameter alarms events and associated parameter
 
ECG
- Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
- Protection: Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof
- Gain: 2.5mm/mV (×0.25), 5.0mm/mV (×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto
- Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
- ECG signal range:  ±12 mV (Gain × 0.25)
- Accuracy: ±1bpm/ ±1%, whichever is greater
- Resolution: 1 bpm
- Leakage Current < 10 μA
- Baseline Recovery:
≤ 3s after defibrillation (Monitor mode)
≤ 1s after defibrillation (Surgery mode)
- Bandwidth:Surgery 1 ~ 25 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 120 Hz
- Indication of Electrode Separation: Every electrode (exclusive of RL)
 
Heart Rate
- Measure range:
Adult: 0bpm; 10 ~ 300 bpm
Neo/Ped: 0bpm; 10 ~ 350 bpm
- Resolution: 1 bpm
- Accuracy: ± 1% or ± 1bpm, whichever is greater
 
 
 
 
ST Measurement
- Range: -2.0 ~ +2.0 mV
- Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
- Other range: unspecified
- Resolution: 0.01mV
 
Respiration
- Method: Impedance between RA-LL, RA-LA
- Gain: ×0.25, ×0.50, ×1, ×2, ×4
- Respiration Rate: 0bpm, 6 ~ 150 BrPM
- Sweep speed:  6.25 mm/s, 12.5 mm/s, 25mm/s
- Resolution: 1 BrPM
- Accuracy: ±2 bpm or ±2%, whichever is greater
- Apnea Alarm: 10 ~ 60 s
 
NIBP
- Method: Oscillometric
- Measure mode: Manual, Auto, STAT
- Measure Interval in AUTO Mode 1~480 min
- STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
- Measure and Alarm Range:
Adult: SYS:  30 ~ 270 mmHg
          DIA:  10 ~ 220 mmHg     
          MEAN:  20 ~ 235 mmHg
Pediatric: SYS:  40 ~ 235 mmHg
DIA:  10 ~ 220 mmHg     
MEAN:  20 ~ 225 mmHg
Neonate:  SYS:  30 ~ 135 mmHg
DIA:  10 ~ 110 mmHg     
MEAN:  20 ~ 125 mmHg
- Static pressure accuracy: ±3mmHg
- Resolution: 1mmHg
- Accuracy: Maximum Mean error ±5mmHg           
         Maximum Standard deviation ≤8mmHg
- Over pressure Protection: Dual protection via software & hardware
 
Temperature
- Technique: Thermistor probe (2.25K)
- Channel: Dual-Channel, provide T1; T2; ΔT
- Measuring and Alarm Range:
0.0 ℃~ 50 ℃ (32℉~ 122℉)
- Unit: Celsius (℃), Fahrenheit ( ℉)
- Resolution: 0.1℃or 1℉
- Accuracy: ±0.1℃(exclusive probe)

Performance Specifications
 
SpO2 (Digital Technic)
- Measurement Range: 0 ~ 100 %
- Resolution: 1 %
- Response Modes: Low, Medium, High
- Accuracy:  ±2% (70% ~ 100%)
            ±3 % (35% ~ 69%)
Unspecified (0 ~ 34%)
- Support Pitch tone and multi-level volume   
 
Pulse Rate
- Measuring and Alarm Range: 25~250bpm
- Accuracy: ±1% or ±1 bpm, whichever is greater
- Resolution: 1bpm
 
Nellcor-SpO2 (Option)
- Measurement Range: 0 ~ 100 %
- Resolution: 1 %
- Accuracy:   70% ~ 100%, ±2 % (adult)
             70% ~ 100%, ±3 % (Neonate)
             70% ~ 100%, ±2 % (Low Perfusion)
             0% ~ 69%, unspecified
 
Pulse Rate
- Measurement range: 20 ~ 300 bpm
- Resolution: 1bpm
- Accuracy:
±3 bpm (20 ~ 250 bpm)
unspecified (251~300 bpm)
 
Masimo SpO2 (Option)
- - Measurement Range: 0 ~ 100 %
- - Resolution: 1 %
- Accuracy:  
70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions)
70% ~ 100%, ±3 % (neonate, non-motion conditions)
70% ~ 100%, ±3 % (motion conditions)
0% ~ 69% unspecified
Pulse Rate
- Measurement range: 25 ~ 240 bpm
- Resolution: 1bpm
- Accuracy: ±3 bpm (non-motion condition)
 
 
 
 
 
 
 
EtCO2 (Mainstream/ Sidestream) (Option)
- Measure method:  Non-dispersive infrared (NDIR)
- Measure Range:  0 ~19.7% (0 ~ 150 mmHg)
                 0 ~ 20 kPa
- Resolution: 0.1 mmHg
- CO2 Accuracy:  
0 ~ 40 mmHg, ±2 mmHg
41 ~ 70 mmHg, ±5% of reading
71 ~ 100 mmHg, ±8% of reading
101~ 150 mmHg, ±10% of reading
at 760 mmHg, ambient temperature of 25℃)
- Respiratory Rate:  Range: 3 ~150 BrPM
                Accuracy: ±1 bpm
 
EtCO2 (Micro-stream) (Option)
- Measure method:  Non-dispersive infrared (NDIR)
- Measure Range:  0 ~19.7% (0 ~150 mmHg)
                 0 ~ 20 kPa
- Sample Rate: 50 mL/min ±10mL/min
- Resolution:  0.1 mmHg (0 ~ 50 mmHg)
           0.25 mmHg (50 ~ 114 mmHg)
- CO2 Accuracy:  0 ~ 40 mmHg, ±2 mmHg
                41 ~ 70 mmHg, ±5% of reading
                71 ~ 100 mmHg, ±8% of reading
               101~ 150 mmHg, ±10% of reading
        at 760 mmHg, ambient temperature of 35℃)
- Respiratory Rate: Range: 3 ~120 BrPM
              Accuracy: ±1 bpm
 
Depth of Anesthesia (CSI) (Option)
- EEG sensitivity:  ± 400μV
- Noise: < 2μVp-p, < 0.4μV RMS, 1-250 Hz
- CMRR: > 140 dB
- Input impedance: > 50 Mohm
- Sample rate: 2000 samples/sec, (14 bits equivalent)
- BS%: 0-100, filter 1-42 Hz, 1 sec. display update
- EMG: 0-100 Logarithmic. Filter 75-85 Hz, 1 sec. update
- Alarms: High / Low with user selectable limit
- Artifact rejection: Automatic
- Sensor impedance range: 0 - 10 kOhm / measurement current 0.01 μA
 

 
Multi-gas/O2 (Anesthetic Gas) (Option)
- Method: Infrared absorption
- Gas sorts: CO2, N2O, Des, Iso, Enf, Sevo, Hal,
   O2 (Optional paramagnetic sensor)
- Calibration: Room air calibration performed automatically when changing airway
Airway adapt (< 5 sec)
- Measurement range:
CO2: 0~25%,  N2O : 0~100%                    
O2: 0~100%,  Enf, Iso, Hal: 0~25%,
Sevo, Des: 0~25%
- Data output: Fi and ET values
- Respiration rate: 0~ 150 BrPM
- Other: Up to 5 waveforms displayed
      Agent mixture detection
  MAC value displayed
 
IBP (Option)
- Max Channel: 2
- Measurement way: Thermal resistance way
- Press Sensor:  Sensitivity   5 uV/V/mmHg, ±2%
              Impedance   300 to 3000Ω
- Resolution: 1 mmHg
- Unit: mmKg, kPa, cmH2O
- Transducer sites:  
Arterial Pressure (ART)
Pulmonary Arterial (PA)
Left Arterial (LAP)
Right Arterial (RAP)
Central Venous Pressure (CVP)
Intracranial Pressure (ICP)
P1/ P2
- Measuring and alarm range:
ART   0 ~ +350mmHg
PA    -10 ~ +120 mmHg
CVP/ RAP/ LAP/ ICP-10 ~ +40 mmHg
P1/ P2-50 ~ +350mmHg
- Accuracy:  
Static: ±1mmHg or ±2%, whichever is greater (exclusive of transducer)
      ±4mmHg or ±4%, whichever is greater (inclusive of transducer)
Dynamic:  ±4mmHg or ±4%, whichever is greater

 
 
The YSF9 patient monitor is designed to match the pace and unique needs of adult, pediatric,
and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments.
 
An optional USB Mouse/Keyboard control eases navigation and data entry.
 
An optional HDMI output eases observation from a long distance.
Yuesen Med equipment purchase process
احصل على السعر
اكتب طلبك أدناه وسنتصل بك في غضون 24 ساعة!

YOUR MAY ALSO LIKE ...
جهاز مراقبة المريض متعدد المعلمات YSPM80C
جهاز مراقبة المريض متعدد المعلمات YSPM80C
مراقبة المريض متعددة المعلمات YSF8
مراقبة المريض متعددة المعلمات YSF8
COVID-19 متعدد المعلمات مراقبة المريض YSPM-A12
COVID-19 متعدد المعلمات مراقبة المريض YSPM-A12
مقياس تأكسج نبض الأطفال المحمول الشهير YSDP11
مقياس تأكسج نبض الأطفال المحمول الشهير YSDP11