جهاز التنفس الصناعي LCD المحمول 10.4 بوصة YSAV203
رقم البند.: YSAV203
متعدد الوظائف المحمول 10.4 بوصة LCD جهاز التنفس الصناعي YSAV203 غير مكلفة
وصف
Multifunctional Mobile 10.4 Inch LCD Medical Ventilator Machine YSAV203
YSAV203 is a multi-functional Ventilator, it is applicable for children and adults in sickroom, ICU or of emergency.
YSAV203 Technical Details
YSAV203 Technical Details
Display mode | 10.4 High-definition” TFT color LCD screen display | |
Ventilation mode | VCV, PCV, SIMV, PSV, PSV+SIMV, CAP | |
Ventilation function | PEEP, SIGH, standby, IP, IRV | |
Ventilation parameters | Tidal volume | 200~1800 ml |
Rate | 2~120 bpm | |
SIMV rate | 2~20 bpm | |
I:E | 4:1~1:8 | |
Inspiratory trigger pressure | -10~100cmH2O | |
Flow trigger sensitivity | 1~20L/min | |
PEEP | 0~25 cmH2O | |
Pressure control | 3~25 cmH2O | |
Pressure limitation | 5~60 cmH2O | |
Pressure slope | 1~10gear | |
Flow rate setting | 1~10gear | |
Expiratory trigger sensitivity | 10%~90% | |
Time control | 1~10s | |
SIGH | 1.5 times the inspiratory time (60~120 adjustable) |
|
Inspiratory platform | 0~50% | |
Oxygen concentration | 21%~99% | |
Parameters for ventilation monitoring | Expired tidal volume, Inhale tidal volume, Minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous breathing rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform, oxygen concentration, battery capacity, pressure – time waveform, flow rate – time waveform, flow-volume loop, pressure-volume loop | |
Security Alarm System | ||
Oxygen Concentration alarm | upper limit setting range 21%~99% low limit setting range 18%~80% |
|
Airway pressure alarm alarm | upper limit setting range 5~60 cmH2O low limit setting range 0~50 cmH2O |
|
minute ventilation volume alarm | upper limit setting range 1~20 L/min low limit setting range 0~19 L/min |
|
Tidal volume | upper limit setting range 10~1800 ml low limit setting range 0~1700 ml |
|
Respiratory rate | upper limit setting range 10~99 bpm low limit setting range 0~50 bpm |
|
Sustained high-pressure alarm | it will give alarm when stress have consistently been higher than 30 cmH2O |
|
Suffocation alarm | it will give sound and light alarm if there is no tidal volume input for 15 seconds | |
Low pressure of Oxygen alarm | Intubation off alarm | |
Low pressure of Air alarm | Battery voltage alarm | |
Power alarm | ||
Power | AC 220V±10% 50Hz±1Hz UPS, Storage battery |
|
Mechanical Arms | ||
End-expiratory | CO2 monitoring(choose and match) | |
Mechanical Arms |