Incubadora infantil de transporte neonatal médico YSBB-200C
Artículo No.: YSBB-200C
Incubadora infantil de transporte neonatal médico a la venta a buen precio.
Parametros del producto | |
Marca: | YSENMED |
MOQ: | 1 |
Paquete: | Paquete de madera |
Nave de: | Guangzhou |
Tiempo de espera: | 1-3 días |
Personalización: | Yes |
Descripción
Incubadora infantil de transporte neonatal médico
STANDARD FEATURES:
●Servo Control Mode: air temperature, skintemperature;
● Parameter Displaying: set temperature,air temperature, skin temperature, internal humidity, heat power rate;
● Audible & Visual Alarms: powerfailure, sensor failure, higher & lower temp, air & skin temperature override,fan failure, system failure;
● >37℃Preset Mode: power failure reset memory, alarm silence, keypad lock, self-testfunction;
● Hood with dual slope; 6 hand-ports;
● RS-232 Output Connector (use for networksystem);
●IV poles;
●Protective guard rail;
●Storage cabinets.
Specifications of hood
Mattress to Hood: 450 mm
Observation side of hood: Two incline
Operate port: 6 (2 Iris ports)
Tubing grommets: 4
Front access panel: 826×310 mm
Mattress Tray Size: 630×360 mm
Technical Specifications:
Powerrequirement ≤400VA
Temperaturecontrol mode: Air and skin servo control
AirTemp Control Range: 20℃~37℃
Temperatureoverride mode to: 20℃~39℃
SkinTemp Control Range: 30℃~37℃
Temperatureoverride mode to: 30℃~38℃
Skintemp sensor accuracy: ≤0.3℃
Temperaturefluctuation: ≤0.5℃
Mattresstemperature uniformity: ≤0.8℃
Temperaturerise time: ≤45 min
Noiselevel within hood environment: ≤55dB
Alarms
Power failure alarm
Fan failure alarm
Sensor failure alarm
High air temperature alarm: +3.0℃
Low airtemperature alarm: -3.0℃
High skin temperature alarm: +1.0℃
Low skin temperature alarm: -1.0℃
Over air temperature alarm: ≤38.0℃; ≤40.0℃
Over skin temperature alarm: ≤38.0℃; ≤39.0℃
Systemfailure alarm
Alarmsilence function
Operational condition
Environment temperature: +20℃~+30℃
Environment relative humidity: 5%~99%
Environment air velocity of flow: <0.3m/s
Others
Infant bed tilt adjusting ±10° step-less
Mattress tray Max. load 10kg
Transfusion pole Max. load 2kg
CabinetMax. load 6kg
●Servo Control Mode: air temperature, skintemperature;
● Parameter Displaying: set temperature,air temperature, skin temperature, internal humidity, heat power rate;
● Audible & Visual Alarms: powerfailure, sensor failure, higher & lower temp, air & skin temperature override,fan failure, system failure;
● >37℃Preset Mode: power failure reset memory, alarm silence, keypad lock, self-testfunction;
● Hood with dual slope; 6 hand-ports;
● RS-232 Output Connector (use for networksystem);
●IV poles;
●Protective guard rail;
●Storage cabinets.
Specifications of hood
Mattress to Hood: 450 mm
Observation side of hood: Two incline
Operate port: 6 (2 Iris ports)
Tubing grommets: 4
Front access panel: 826×310 mm
Mattress Tray Size: 630×360 mm
Technical Specifications:
Powerrequirement ≤400VA
Temperaturecontrol mode: Air and skin servo control
AirTemp Control Range: 20℃~37℃
Temperatureoverride mode to: 20℃~39℃
SkinTemp Control Range: 30℃~37℃
Temperatureoverride mode to: 30℃~38℃
Skintemp sensor accuracy: ≤0.3℃
Temperaturefluctuation: ≤0.5℃
Mattresstemperature uniformity: ≤0.8℃
Temperaturerise time: ≤45 min
Noiselevel within hood environment: ≤55dB
Alarms
Power failure alarm
Fan failure alarm
Sensor failure alarm
High air temperature alarm: +3.0℃
Low airtemperature alarm: -3.0℃
High skin temperature alarm: +1.0℃
Low skin temperature alarm: -1.0℃
Over air temperature alarm: ≤38.0℃; ≤40.0℃
Over skin temperature alarm: ≤38.0℃; ≤39.0℃
Systemfailure alarm
Alarmsilence function
Operational condition
Environment temperature: +20℃~+30℃
Environment relative humidity: 5%~99%
Environment air velocity of flow: <0.3m/s
Others
Infant bed tilt adjusting ±10° step-less
Mattress tray Max. load 10kg
Transfusion pole Max. load 2kg
CabinetMax. load 6kg