catégories
5kW Machine de radiographie diagnostique à haute fréquence mobile YSX100GM
No. d'article: YSX100GM
5kW Machine de radiographie diagnostique à haute fréquence mobile YSX100GM
Paramètres du produit | |
Marque: | YSENMED |
MOQ: | 1 |
Paquet: | Paquet de carton |
Expédier de: | Guangzhou |
Délai: | 1 à 3 jours |
Personnalisé: | Yes |
Description
5kW Machine de radiographie diagnostique à haute fréquence mobile YSX100GM
Technique Specification
Model | YSX70GM-B | YSX100GM | |
Power | |||
Input Voltage | 220V±10% | ||
Input Power | 5.5kW | 7.5kW | |
Mains Frequency | 50Hz±1Hz | ||
Source Resistance | ≤0.5Ω | ||
Main Technical Parameters | |||
Power Modules | 30kHz | ||
Filament Frequency | 20kHz | ||
Focus | 1.5mm | ||
Max. Generator Output | 3.5kW; | 5kW | |
Max. X-Ray Tube Voltage | 110KV | 120KV | |
kV Range | 40~120kV | ||
mAs Range | 1~125mAs | 1~200mAs | |
Main Parameters Of Mechanical Parts | |||
X Ray Tube Vertical Motion Range | ≥500~1750mm | ||
X Ray Source Components Around The Cross Arm Vertical Rotation:≥±90° | |||
Exposure Size | ≥350mm*350mm(SID=65cm) | ||
Machine Main Function | |||
Fault Detection Error Prompt Functions | |||
ARP Human Anatomy Program Function | |||
Parameter Calibration Function |
Combined X-Ray Tube Assembly
1,Adopt high frequency high voltage generator and combined X-ray tube assembly;
2,kV closed-loop control, stable output, good repeatability, quick response and high accuracy;
3,mAs digital closed-loop control technology and 32-bit microprocessor real-time control, which ensure the accuracy and repeatability of dosage;
Inverter
1,Equipped with the functions of high voltage and over & under voltage protection, tube current over-current protection, output overload protection and fault prompt;
2,Perfect heat capacity protection function to protect X-ray tube target surface;
Corrugated Pipe
Full consideration of hospital disinfection and cleaning, adopt high quality corrugated pipe, prolonging the service life of the equipment
Switch
Using high quality switch, safe and reliable, stable quality
Technique Specification
Model | YSX70GM-B | YSX100GM | |
Power | |||
Input Voltage | 220V±10% | ||
Input Power | 5.5kW | 7.5kW | |
Mains Frequency | 50Hz±1Hz | ||
Source Resistance | ≤0.5Ω | ||
Main Technical Parameters | |||
Power Modules | 30kHz | ||
Filament Frequency | 20kHz | ||
Focus | 1.5mm | ||
Max. Generator Output | 3.5kW; | 5kW | |
Max. X-Ray Tube Voltage | 110KV | 120KV | |
kV Range | 40~120kV | ||
mAs Range | 1~125mAs | 1~200mAs | |
Main Parameters Of Mechanical Parts | |||
X Ray Tube Vertical Motion Range | ≥500~1750mm | ||
X Ray Source Components Around The Cross Arm Vertical Rotation:≥±90° | |||
Exposure Size | ≥350mm*350mm(SID=65cm) | ||
Machine Main Function | |||
Fault Detection Error Prompt Functions | |||
ARP Human Anatomy Program Function | |||
Parameter Calibration Function |
Combined X-Ray Tube Assembly
1,Adopt high frequency high voltage generator and combined X-ray tube assembly;
2,kV closed-loop control, stable output, good repeatability, quick response and high accuracy;
3,mAs digital closed-loop control technology and 32-bit microprocessor real-time control, which ensure the accuracy and repeatability of dosage;
Inverter
1,Equipped with the functions of high voltage and over & under voltage protection, tube current over-current protection, output overload protection and fault prompt;
2,Perfect heat capacity protection function to protect X-ray tube target surface;
Corrugated Pipe
Full consideration of hospital disinfection and cleaning, adopt high quality corrugated pipe, prolonging the service life of the equipment
Switch
Using high quality switch, safe and reliable, stable quality
YOUR MAY ALSO LIKE ...
YSENMED YSX-mDR32 32kW 400mA Medical Digital Mobile X-ray Machine
Appareil de radiographie de diagnostic médical mobile YSX200GM-B 20KW / 200mA HF