GE Mobile X-ray machine fault

Views : 897
Author : Monica Liang
Update time : 2015-12-21 08:00:00

The machine over-current protection contactor triped and system was automatic power off when open the machine and pressed positioning lamp or exposure preparation in use.

Failure analysis and maintenance:

AMX-4+ system is consist of power box, charging control, CPU board, high voltage generator, motor control and remote control receiving. Every model is controled and detected by CPU. Then check attached machine circuit diagram and consider that positioning lamp(AC 24V, 150W) and exposure preparation(Rotating anode start ) are provided power by T1 transformer, it is controled by 46-232786G2.

The next step you could take down the board and measure, you would find that F93, which had insurance tube, is burned off and effective tube was breakdown. After replacing the same model tube, connect power and open the machine, fault remains. Then you would doubt CPU control singal abnormal and increase the load spurious. It leads to excessive current and power tube punctured. The following you could use digital multimeter to measure and 60Hz control singal is normal.

Replace the tube again and then connect power, the two test points are 5V and 6V. This two points are not balance. After power off, take down promote tube Q61, there is leakage phenomenon. After replacing the same model tube, connect power and measure two points are 6.0V. After opening the machine and self-inspection, fault is solved and x-ray machine can work normally.

Related News
Read More >>
Demostration video of YSENMED YSX-Mini1 Handheld Digital X-ray Unit. Demostration video of YSENMED YSX-Mini1 Handheld Digital X-ray Unit.
Dec .22.2024
Here we share the demostration video of YSENMED YSX-Mini1 Handheld Digital X-ray Unit.
Thai vet satisfied with YSENMED YSFPD-M1717V Vet flat panel detector & after-sale service Thai vet satisfied with YSENMED YSFPD-M1717V Vet flat panel detector & after-sale service
Dec .21.2024
A Thai vet clinic digitizes its analog x-ray system with YSENMED YSFPD-M1717V VET flat panel detector, and the vet is very satisfied with the quality images and our after-sale service.
Tech Meets Care: The Science Behind Mastopathy Treatment Devices Tech Meets Care: The Science Behind Mastopathy Treatment Devices
Dec .21.2024
In this article, we'll dive into the fascinating intersection of technology and healthcare, exploring how innovative devices are transforming mastopathy treatment.
YSENMED LED operation lamp installed in a vet clinic in Greece YSENMED LED operation lamp installed in a vet clinic in Greece
Dec .20.2024
YSENMED LED operation lamp with endoscope mode YSOT-LED5B+LED3B has got installed in a vet clinic in Greece, and the vet feels happy and satisfied with it.