GE Mobile X-ray machine fault

Views : 885
Author : Monica Liang
Update time : 2015-12-21 08:00:00

The machine over-current protection contactor triped and system was automatic power off when open the machine and pressed positioning lamp or exposure preparation in use.

Failure analysis and maintenance:

AMX-4+ system is consist of power box, charging control, CPU board, high voltage generator, motor control and remote control receiving. Every model is controled and detected by CPU. Then check attached machine circuit diagram and consider that positioning lamp(AC 24V, 150W) and exposure preparation(Rotating anode start ) are provided power by T1 transformer, it is controled by 46-232786G2.

The next step you could take down the board and measure, you would find that F93, which had insurance tube, is burned off and effective tube was breakdown. After replacing the same model tube, connect power and open the machine, fault remains. Then you would doubt CPU control singal abnormal and increase the load spurious. It leads to excessive current and power tube punctured. The following you could use digital multimeter to measure and 60Hz control singal is normal.

Replace the tube again and then connect power, the two test points are 5V and 6V. This two points are not balance. After power off, take down promote tube Q61, there is leakage phenomenon. After replacing the same model tube, connect power and measure two points are 6.0V. After opening the machine and self-inspection, fault is solved and x-ray machine can work normally.

Related News
Read More >>
Australian vet clinic digitizing its x-ray with YSFPD-M1717V Vet DR panel Australian vet clinic digitizing its x-ray with YSFPD-M1717V Vet DR panel
Nov .21.2024
Australian vet clinic upgrades its analog x-ray system by bringing in YSENMED YSFPD-M1717V Vet wireless flat panel detector.
Bolivian doctor satisfied with YSB-C10RL USB & WIFI color ultrasound probe and considers re-purchasing Bolivian doctor satisfied with YSB-C10RL USB & WIFI color ultrasound probe and considers re-purchasing
Nov .20.2024
Bolivian doctor is satisfied with our USB & WIFI color doppler ultrasound probe YSB-C10RL, and considers re-purchasing another two pieces.
Two veterinary hematology analyzers YSTE320V starting to serve in a vet clinic in Honduras. Two veterinary hematology analyzers YSTE320V starting to serve in a vet clinic in Honduras.
Nov .19.2024
Two veterinary hematology analyzers have arriaved at a vet clinic in Honduras and the vet is happy with them.
From Lab to Life: How Automated Blood Component Separators Enhance Patient Care From Lab to Life: How Automated Blood Component Separators Enhance Patient Care
Nov .17.2024
Let's dive into the world of the automated blood component separator and discover how it transforms lives.