GE Mobile X-ray machine fault

Views : 924
Author : Monica Liang
Update time : 2015-12-21 08:00:00

The machine over-current protection contactor triped and system was automatic power off when open the machine and pressed positioning lamp or exposure preparation in use.

Failure analysis and maintenance:

AMX-4+ system is consist of power box, charging control, CPU board, high voltage generator, motor control and remote control receiving. Every model is controled and detected by CPU. Then check attached machine circuit diagram and consider that positioning lamp(AC 24V, 150W) and exposure preparation(Rotating anode start ) are provided power by T1 transformer, it is controled by 46-232786G2.

The next step you could take down the board and measure, you would find that F93, which had insurance tube, is burned off and effective tube was breakdown. After replacing the same model tube, connect power and open the machine, fault remains. Then you would doubt CPU control singal abnormal and increase the load spurious. It leads to excessive current and power tube punctured. The following you could use digital multimeter to measure and 60Hz control singal is normal.

Replace the tube again and then connect power, the two test points are 5V and 6V. This two points are not balance. After power off, take down promote tube Q61, there is leakage phenomenon. After replacing the same model tube, connect power and measure two points are 6.0V. After opening the machine and self-inspection, fault is solved and x-ray machine can work normally.

Related News
Read More >>
Measuring Eye Health: The Role of an Ophthalmic Biometer & Pachymeter Explained Measuring Eye Health: The Role of an Ophthalmic Biometer & Pachymeter Explained
Jan .17.2025
In this article, we'll dive deep into what ophthalmic biometers and pachymeters do, how they work, and why they're so important for your eye health.
Seeing Clearly: The Role of Ophthalmic Surgery Microscopes in Vision Restoration Seeing Clearly: The Role of Ophthalmic Surgery Microscopes in Vision Restoration
Jan .16.2025
Let's dive into the fascinating world of ophthalmic surgery microscopes and explore how they contribute to vision restoration.
Seeing Clearly: How Digital Hand-held Slit Lamps Make Eye Exams a Breeze Seeing Clearly: How Digital Hand-held Slit Lamps Make Eye Exams a Breeze
Jan .15.2025
In this article, we'll explore how digital hand-held slit lamps are revolutionizing eye care and making exams easier for both patients and doctors.
What Makes Flexible Anesthesia Video Laryngoscopes a Must-Have for Airway Care? What Makes Flexible Anesthesia Video Laryngoscopes a Must-Have for Airway Care?
Jan .14.2025
Let's dive into this fascinating topic and explore the benefits, technology, and real-world applications of flexible anesthesia video laryngoscopes.