We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.

Professional Medical Equipment Supplier - Yuesen Med Professional Medical Equipment Supplier - Yuesen Med

Hot Products

X Ray Machine  To  Zimbabwe

x ray machine, 50KW x ray machine

Microscope To Malawi

Achromatic objectives: 4X、10X、40X(S), 100X(S、Oil) Wide field eyepiece: WF10X(WF16X for option) Eyepiece head: Sliding binocular head inclined at 45° Stage: Double layer mechanical stage size 140X140mm, moving range 75X45mm Focusing: Coaxial coarse and

Color Doppler Trolley System To Somalia

Color Doppler Trolley System To Somalia

Automated Hematology Analyzer To Peru

High quality Automated Hematology Analyzer (3-part differential) with cheap price

GE Mobile X-ray machine fault

Views : 849
Author : Monica Liang
Update time : 2015-12-21 08:00:00

The machine over-current protection contactor triped and system was automatic power off when open the machine and pressed positioning lamp or exposure preparation in use.

Failure analysis and maintenance:

AMX-4+ system is consist of power box, charging control, CPU board, high voltage generator, motor control and remote control receiving. Every model is controled and detected by CPU. Then check attached machine circuit diagram and consider that positioning lamp(AC 24V, 150W) and exposure preparation(Rotating anode start ) are provided power by T1 transformer, it is controled by 46-232786G2.

The next step you could take down the board and measure, you would find that F93, which had insurance tube, is burned off and effective tube was breakdown. After replacing the same model tube, connect power and open the machine, fault remains. Then you would doubt CPU control singal abnormal and increase the load spurious. It leads to excessive current and power tube punctured. The following you could use digital multimeter to measure and 60Hz control singal is normal.

Replace the tube again and then connect power, the two test points are 5V and 6V. This two points are not balance. After power off, take down promote tube Q61, there is leakage phenomenon. After replacing the same model tube, connect power and measure two points are 6.0V. After opening the machine and self-inspection, fault is solved and x-ray machine can work normally.

Related News
Read More >>
A Philippine hospital digitizes its analog mammography system with YSENMED YSFPD-R1012C mammo flat panel detector A Philippine hospital digitizes its analog mammography system with YSENMED YSFPD-R1012C mammo flat panel detector
Sep .16.2024
A Philippine hospital has digitized its analog mammography x-ray system with YSENMED mammo flat panel detector YSFPD-R1012C, and the doctor is happy with the images and service.
A Brazilian vet clinic fully equipped with YSENMED veterinary care equipment A Brazilian vet clinic fully equipped with YSENMED veterinary care equipment
Sep .15.2024
A Brazilian vet clinic has been well equipped with veterinary care equipment supplied by YSENMED, in which there are 20kW veterinary mobile digital x-ray system YSX-mDR20 VET, veterinary color doppler ultrasound system YSB-S7V, veterinary hematology analy
YSX-iDR50E 50kW digital x-ray machine set up in a Kazakhstani hospital YSX-iDR50E 50kW digital x-ray machine set up in a Kazakhstani hospital
Sep .14.2024
YSENMED 50kW motorized digital x-ray system YSX-iDR50E has been successfully installed in a hospital in Kazakhstan.
Philippinese doctor satfisfied with the images by Mars 1717V wireless detector. Philippinese doctor satfisfied with the images by Mars 1717V wireless detector.
Sep .10.2024
Philippinese hospital upgraded its x-ray system with YSENMED wireless flat panel detector Mars 1717V, and they are satfisfied with the images.