23L hospital automatic steam sterilizer laboratory autoclave YSMJ-VRY-A23

Item No.: YSMJ-VRY-A23
23L hospital automatic steam sterilizer laboratory autoclave YSMJ-VRY-A23
Get Price
Description
23L hospital automatic steam sterilizer laboratory autoclave YSMJ-VRY-A23
23L hospital automatic steam sterilizer laboratory autoclave

Constructure Feature and Application Scope
The accessories of Sterilization include: Sterilization Chamber, Door unit, Insulation unit, Pipe system, Safety valve, Control system, Storage tanks, waste water tank, Steam generator and so on
 The vacuum pump pulsates three times creating less residual air in the chamber to ensure better sterilization effect.
The LCD screen show all sterilization data, which ensure better control of the sterilization process
Safety valve installed in sterilizer, when pressure beyond 0.27Mpa. The balance pressure can be released by safety valve to ensure safe operation.
The instrument has a self-protect feature. When the water tank Lack of water or drainage water tank is full, the machine will finished the currently sterilization cycle but can not start the next operation unless add water is added or drainage is complete. There will be buzzer to remind users to add or drain water
This product can be applied in the tooth device, operation device, sanitary material and other heat-resisting articles existing in the Dept. of stomatology, ophthalmology surgery and lab.


Tech. Parameter
Inner chamber of the Sterilizer (Diameter X Depth): 
12L:200mm X 360mm 16L: 229mm X 360mm
18L:245mm X 350mm 23L: 245mm X150MM
Sterilizer product size(length*width*height):
23L:660mm X 442mm X 380mm
18L:540mm X 442mm X 380mm
Related Voltage: 220V/50Hz, 110V/60Hz
Related Power: 1800w
Sterilization(Pressure/Temperature):
90~130KPa/121℃(standard atmospheric pressure)
20~230KPa/134℃(standard atmospheric pressure)
Safety Grade: Grade I
Fuse: T15A
Water tank Capacity: 2L
Each cycle water consumption: 0.3L
Minimum tank level alarm: 0.5L
Operate Temperature: 0~40℃



Yuesen Med equipment purchase process 
23L hospital automatic steam sterilizer laboratory autoclave YSMJ-VRY-A23
Get Price
Write down your demand below and we will contact you within 24h!

YOUR MAY ALSO LIKE ...
Visible Spectrophotometer YSTE-V5000
Visible Spectrophotometer YSTE-V5000
UV/VIS Spectrophotometer YSTE-UV5100B
UV/VIS Spectrophotometer YSTE-UV5100B
UV/VIS Spectrophotometer  YSTE-UV5600
UV/VIS Spectrophotometer YSTE-UV5600
Total Organic Carbon Analyzer Price YSTE-TOC1500
Total Organic Carbon Analyzer Price YSTE-TOC1500