YSPM620V Veterinary Patient Monitor
Item No.: YSPM620V
Product parameters | |
Brand: | YSENMED |
MOQ: | 1 |
Package: | Carton Package |
Ship From: | Guangzhou |
Lead Time: | 3-5 days |
Customization: | Customized package |
Description
Function and Features
1、6-Vital signs numerical results and waveform are shown on the TFT-LCD in real time.2、Communication with other intelligent terminals via Bluetooth.
3、Automatically power off to save power.
4、Portable, palm size
5、Low power consumption.
6、One touch operation
7、APP for Android and iOS
8、Real time data transmission
9、Rechargeable battery and wireless charging
10、Can be used while charging
11、Lithium battery is builtin.
12、Multi-function for SpO2, HR, Temp, ECG, RR and NIBP
Technical Features
Display ECG, HR, NIBP, SpO2, PR, TEMP | Screen: 2.8 inches colorized TFT-LCD screen |
ECG Waveform: Lead I Band width 0.05Hz ~ 100Hz(3dB) diagnose mode 1 ~ 40Hz monitor mode 0.1 ~ 25Hz operation mode |
Heart rate: Scope: 15 bpm ~ 300 bpm Accuracy:±2bpm or 2%, whichever is greater. |
NIBP Scope: Systolic blood pressure: 4kPa ~ 34kPa(30mmHg ~ 255mmHg) Diastolic pressure: 2kPa ~ 29.3kPa(15mmHg ~ 220mmHg) Mean pressure: 2.7kPa ~ 31.3kPa (20mmHg ~ 235mmHg) Detection accuracy: Static pressure: ±3mmHg |
Temp: Type: Vascular/surface temperature Scope: 25℃ ~ 45℃ Accuracy: ±0.2℃ |
RESP Measurement range: 5~100brpm. Accuracy:±2brpm |
TEMP Measurement range: 25~45℃. Measurement accuracy: ±0.2℃. |
SpO2 Measurement range:35~100%. Accuracy: ±2% (80%~100%), ±3% (70%~79%), ±3% (35%~69%) |
PR Measurement range: 25~250bpm. Accuracy: ±2bpm or 2%, whichever is greater. |
NIBP: Scope: Systolic blood pressure: 4kPa ~ 34kPa (30mmHg ~ 255mmHg) Diastolic pressure: 2kPa ~ 29.3kPa (15mmHg ~ 220mmHg) Mean pressure: 2.7kPa ~ 31.3kPa (20mmHg ~ 235mmHg) Detection accuracy: Static pressure: ±3mmHg |
Weight: 256±10g (n |