HPLC Fully Auto Glycated Hemoglobin Analyzer YSTE760H
Item No.: YSTE760H
HPLC Fully Auto Glycated Hemoglobin Analyzer YSTE760H is Automatic identification system for Primary Tube & sample cup,
Primary tube with cap puncture automatically.
Primary tube with cap puncture automatically.
Product parameters | |
Brand: | YSENMED |
MOQ: | 1 |
Package: | Standard Package |
Ship From: | Guangzhou |
Lead Time: | 3-15 days |
Customization: | yes |
Description
HPLC Fully Auto Glycated Hemoglobin Analyzer YSTE760H
Easy Operation
○No Sample Pre-treatment
○Fully automated operation saves time and labor
○Automatic Primary tube sampling with cap puncture
○Auto identificate the whole blood or lyse
○STAT capability
○Batch sampling offer flexibility in workflow
○3.0 Mins per sample
Easy Maintenance
○ No special tools required for daily maintenance.
○ Online Alarm message for Buffer insufficient
○ Fully modular design, if fault occurs, can find the damaged parts quickly and accurately, solve problems with fastest response.
○Superior performance LED detector, long life-span, no need pre-heat,
○Temperature range for column 5-40℃, can keep the constant temperature, the fluctuation ±0.2℃
○High stability Pump to ensure the Hemoglobin separation, Maximum withstand pressure 200kg/cm2(2900psi), pressure sensitivity, fluctuation ±5%
Superior HbA1c Accuracy
○ HbA1C Standardization-compatible according to IFCC
○The measurement result includes information of each peak and chromatogram both of which can be utilized for analysis.
○ Superior Quality chromatographic resolution to eleminate interferences.
○ It provides direct determination of stable HbA1c(SA1c) with less than 2% CVs.
QC/Calibration
○ Automatic Calibration, Can correspond to IFCC & NGSP, get reliable result.
○Built-in quality control management simplifies quality assurance compliance
Performance | |
Method | HIGH pressure ion exchange liquid chromatography (HPLC) |
Instrument | Fully-Auto Glycated Hemoglobin HbA1c Analyzer |
Sampling system | Automatic identification system for Primary Tube & sample cup, Primary tube with cap puncture automatically |
Throughput | ≤3mins per sample |
Sample Tray | 15 samples position, CAL1(QC1) & CAL2(QC2)position, ST |
Sample Type | Venous Blood, Finger Peripheral Blood, or hemolyse blood |
Sample Volume | 5ul whole blood, or lyse blood (ratio 5ul:1000ul) |
Test Range | HbA1c: 3-18%; 14-191mmol/mol, HbF:0.3-5% |
Test Item | HbA1c HbF & β-Thalassemia |
Heat system | Temperature range for column 5-40℃, can keep the constant temperature, the fluctuation £±0.2℃ |
Light system | 415nm LED light, long life span, the fluctuation is £2mv per hour |
Printer | 57nm Thermal printer, printing test curve and report |
USB Port | Support LIS system, software upgrade online, external barcode scanner optional |
Barcode | External barcode scanner optional |
Display | 8 inch LCD colorful touch screen, 162mm´122mm, display real-time testing curve |
Data Storage | more than 10,000 test reports storage (including Curve),Inquiry freely |
Language | English, Spanish, Russians, Portuguese, Japanese…… |
Report | NGSP, IFCC result HbA1a, HbF, HbA1c, HbA0,HbA2 variant sample report. Optional PC software for regular report format |
Work Condition | Temperature 5℃~30℃, Relative humidity 30%~75% |
Power supply | 110V-220V, 50-60Hz |
Dimension | 460mm×445mm×390mm |
Weight | 28KGS |
Precision
Within-Run(n=20) | Inter-Run(n=20) | |||
Low | High | Low | High | |
Mean | 5.56 | 10.24 | 5.64 | 10.18 |
SD | 0.08 | 0.09 | 0.12 | 0.15 |
CV(%) | 1.43 | 0.87 | 2.13 | 1.47 |
Comparative Test