We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.

Professional Medical Equipment Supplier - Yuesen Med Professional Medical Equipment Supplier - Yuesen Med

Categories

YSPM-F15M Multi-parameter Modular Patient Monitor (15 inches)

Item No.: YSPM-F15M
This patient monitor is designed to match the pace and unique needs of adult, pediatric, and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments.
Product parameters
Brand: YSENMED
MOQ: 1
Package: Carton Package
Ship From: Guangzhou
Lead Time: 3-5 days
Customization: Customized package
Get Price
Description
Technical Data Sheet - Release V2.2
 

The  F15 patient monitor is designed to match the pace and unique needs of adult, pediatric, and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments.
 
An optional USB Mouse/Keyboard control eases navigation and data entry.
 
An optional HDMI output eases observation from a long distance.
 
Features
 
Core
  1. Newly advanced A9 main board with Linux OS, calculating speed is 4 times faster than traditional products
 
  1. Support storage of 2160 hours trend table and graph review, 2 hours waveform review, 2000 groups NIBP review and 2000 alarm events review
 
Body
  1. 15 inch high-brightness TFT LED
  2. Support display 9~13 waveforms
  3. Support 7 channel ECG waveform display simultaneously  
  4. Optional touch screen
  5. Optional HDMI output
 
Printer
  1. Built-in high-speed 50mm thermal printer
 (Brand: SEIKO, Japan)
 
Central System
  1. Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station.
  2. Optional Support HL7 (Health Level Seven)
Alarm
  1. Three-level acousto-optic alarm
  2. Sensor-off alarm
  3. Paper out alarm
  4. Support alarm review 
  5. Support alarm pause
 
Linux OS
  1. Support operation with mouse and computer keyboard (option)
 
  1. Multi-display mode to meet different clinical requirement, including standard interface, big font, OxyCRG, trend graph, NIBP review and full leads ECG interface.
 
  1. NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
  2. Generate ID automatically when register a new patient
  3. Support medical history search by patient ID, name and mobile number
  4. 18 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
  5. Drug calculation and titration table 
  6. Support multi-language display
  7. Support online software upgrading by net/USB

 Performance Specifications
 
Dimension and Weight
  • Dimension: 380mm*360mm*160mm
  • Weight: 4.5kgexcluding accessories
 
Power Supply
  • Voltage: AC100240V, 50/60HZ, Power≤60W
 
Display
  • 15" color TFT LED  
  • Resolution: 1024*768 pixels
 
Battery (Pluggable)
  • Type: Rechargeable lithium battery 14.8V/2200mAh
  • Charge Cycle: ≥500 times
  • Working time: 2 hours (optional larger battery for 4-5 hours)
 
Recorder (Option)
  • Method: Thermal printer
  • Paper width: 50 mm (1.97 in)
  • Printing speed: 12.5/ 25/ 50 mm/s
  • Trace: Max. 3 tracks
  • Recording way: Real-time Recording, Review Printing,  
    Periodic Recording, Alarm Recording
 
Alarm
  • Level: Low, medium and high
  • Indication: Auditory and visual
  • Alarm volume adjustable
  • Alarm pause time: 1min, 2min
  • Parameter alarm type: Latch/ Unlatch
 
Input Device
  • Touch screen (option)
  • Knob (Standard)
  • Keypad input (Standard)
  • Mouse/ Keyboard input (option)
 
System Output & Extensible Interface
  • Ethernet Network: 1 standard RJ45 socket
  • USB Port: 1
  • Video Output:  1 HDMI port (option)
 
Operating Environment
  • Temperature:  5 ~ 40
  • Humidity:  15% ~ 80% (non-condensing)
  • Atmosphere pressure:  86 KPa ~ 110 KPa
 
 
 
Transportation and Storage Environment
  • Temperature: -2050
  • Humidity: 10%90%  (non-condensing)
  • Atmosphere pressure:  86 KPa ~ 110 KPa
 
Safety
  • IEC60601-1 Approved, CE marking according to MDD93/42/EEC
  • With reference to RoHS Directive 2011/65/EU recasting
 
Trend & Reviewing
  • Trend: 2160 hours
  • ARR events: 128 groups of ARR events and associated waveform
  • NIBP measurement reviewing: 2000 groups
  • Waveform review: 2 hours
  • Alarm event: 2000 groups of parameter alarms events and associated parameter
 
ECG
  • Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
  • Protection: Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof
  • Gain: 2.5mm/mV (×0.25), 5.0mm/mV (×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto
  • Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
  • ECG signal range:  ±12 mV (Gain × 0.25)
  • Accuracy: ±1bpm/ ±1%, whichever is greater
  • Resolution: 1 bpm
  • Leakage Current < 10 μA
  • Baseline Recovery:
≤ 3s after defibrillation (Monitor mode)
≤ 1s after defibrillation (Surgery mode)
  • Bandwidth: Surgery 1 ~ 25 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 120 Hz
  • Indication of Electrode Separation: Every electrode (exclusive of RL)
 
Heart Rate
  • Measure range:
Adult: 0bpm; 10 ~ 300 bpm
Neo/Ped: 0bpm; 10 ~ 350 bpm
  • Resolution: 1 bpm
  • Accuracy: ± 1% or ± 1bpm, whichever is greater
 
 
 
 
ST Measurement
  • Range: -2.0 ~ +2.0 mV
  • Accuracy: -0.8mV+0.8mV: ±0.02mV or ±10%, whichever is greater
  • Other range: unspecified
  • Resolution: 0.01mV
 
Respiration
  • Method: Impedance between RA-LL, RA-LA
  • Gain: ×0.25, ×0.50, ×1, ×2, ×4
  • Respiration Rate: 0bpm, 6 ~ 150 BrPM
  • Sweep speed:  6.25 mm/s, 12.5 mm/s, 25mm/s
  • Resolution: 1 BrPM
  • Accuracy: ±2 bpm or ±2%, whichever is greater
  • Apnea Alarm: 10 ~ 60 s
 
NIBP
  • Method: Oscillometric
  • Measure mode: Manual, Auto, STAT
  • Measure Interval in AUTO Mode 1~480 min
  • STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
  • Measure and Alarm Range: 
Adult: SYS:  30 ~ 270 mmHg
           DIA:  10 ~ 220 mmHg     
           MEAN:  20 ~ 235 mmHg
Pediatric: SYS:  40 ~ 235 mmHg
DIA:  10 ~ 220 mmHg     
MEAN:  20 ~ 225 mmHg
Neonate:   SYS:  30 ~ 135 mmHg
DIA:  10 ~ 110 mmHg     
MEAN:  20 ~ 125 mmHg
  • Static pressure accuracy: ±3mmHg
  • Resolution: 1mmHg
  • Accuracy: Maximum Mean error ±5mmHg           
         Maximum Standard deviation 8mmHg
  • Over pressure Protection: Dual protection via software & hardware
 
Temperature
  • Technique: Thermistor probe (2.25K)
  • Channel:  Dual-channel, provide T1; T2; ΔT
  • Measuring and Alarm Range:
0.0 ~ 50  (32~ 122)
  • Unit: Celsius (), Fahrenheit ( )
  • Resolution: 0.1or 1
  • Accuracy: ±0.1(exclusive probe)
 
SpO2 (Digital Technic)
  • Measurement Range: 0 ~ 100 %
  • Resolution: 1 %
  • Response Modes: Low, Medium, High
  • Accuracy:  ±2% (70% ~ 100%)
            ±3 % (35% ~ 69%)
Unspecified (0 ~ 34%)
  • Support Pitch tone and multi-level volume   
 
Pulse Rate
  • Measuring and Alarm Range: 25~250bpm
  • Accuracy: ±1% or ±1 bpm, whichever is greater
  • Resolution: 1bpm
 
Nellcor-SpO2 (Option)
  • Measurement Range: 0 ~ 100 %
  • Resolution: 1 %
  • Accuracy:   70% ~ 100%, ±2 % (adult)
             70% ~ 100%, ±3 % (Neonate)
             70% ~ 100%, ±2 % (Low Perfusion)
             0% ~ 69%, unspecified
 
Pulse Rate
  • Measurement range: 20 ~ 300 bpm
  • Resolution: 1bpm
  • Accuracy:
±3 bpm (20 ~ 250 bpm)
unspecified (251~300 bpm)
 
Masimo SpO2 (Option)
  • - Measurement Range: 0 ~ 100 %
  • - Resolution: 1 %
  • Accuracy:  
70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions)
70% ~ 100%, ±3 % (neonate, non-motion conditions)
70% ~ 100%, ±3 % (motion conditions)
0% ~ 69% unspecified
Pulse Rate
  • Measurement range: 25 ~ 240 bpm
  • Resolution: 1bpm
  • Accuracy: ±3 bpm (non-motion condition)
 
 
 
 
 
 
EtCO2 (Mainstream/ Sidestream) (Option)
  • Measure method:  Non-dispersive infrared (NDIR)
  • Measure Range:  0 ~19.7% (0 ~ 150 mmHg)
                 0 ~ 20 kPa
  • Resolution: 0.1 mmHg
  • CO2 Accuracy:  
0 ~ 40 mmHg, ±2 mmHg
41 ~ 70 mmHg, ±5% of reading
71 ~ 100 mmHg, ±8% of reading
101~ 150 mmHg, ±10% of reading
at 760 mmHg, ambient temperature of 25)
  • Respiratory Rate:  Range: 3 ~150 BrPM
                Accuracy: ±1 bpm
 
EtCO2 (Micro-stream) (Option)
  • Measure method:  Non-dispersive infrared (NDIR)
  • Measure Range:  0 ~19.7% (0 ~150 mmHg)
                 0 ~ 20 kPa
  • Sample Rate: 50 mL/min ±10mL/min
  • Resolution:  0.1 mmHg (0 ~ 50 mmHg)
           0.25 mmHg (50 ~ 114 mmHg)
  • CO2 Accuracy:  0 ~ 40 mmHg, ±2 mmHg
                41 ~ 70 mmHg, ±5% of reading
                71 ~ 100 mmHg, ±8% of reading
               101~ 150 mmHg, ±10% of reading
        at 760 mmHg, ambient temperature of 35)
  • Respiratory Rate: Range: 3 ~120 BrPM
              Accuracy: ±1 bpm
 
Depth of Anesthesia (CSI) (Option)
  • EEG sensitivity:  ± 400μV
  • Noise: < 2μVp-p, < 0.4μV RMS, 1-250 Hz

Get Price
Write down your demand below and we will contact you within 24h!

YOUR MAY ALSO LIKE ...
YSPM80C Multi-parameter Patient Monitor
YSPM80C Multi-parameter Patient Monitor
12.1 Inch Multi-parameter Patient Monitor YSF8
12.1 Inch Multi-parameter Patient Monitor YSF8
COVID-19 Multi-parameter patient monitor YSPM-A12
COVID-19 Multi-parameter patient monitor YSPM-A12
Popular Portable Pediatric Pulse Oximeter YSDP11
Popular Portable Pediatric Pulse Oximeter YSDP11