Utilizamos cookies para melhorar a sua experiência online. Ao continuar navegando neste site, assumimos que você concorda com o uso de cookies.

Professional Medical Equipment Supplier - Yuesen Med Professional Medical Equipment Supplier - Yuesen Med

Categorias

Equipamento hospitalar médico Multi-parâmetro monitor paciente YSF6

Item número.: YSF6
Equipamento hospitalar médico Multi-parâmetro monitor paciente YSF6
Obtenha o preço
Descrição
Medical hospital equipment Multi-parameter patient monitor YSF6
 
The  F6 patient monitor is designed to match the pace and unique needs of adult, pediatric,
and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments.
Pacemaker detection and Arrhythmia analysis..
 
An optional USB Mouse/Keyboard control eases navigation and data entry.
Humane fashion design and handle of humanized integration design, easy to carry.
 
Designed without fan, characterized with no noise and lower consumption.
Features
 
 
Core
Newly advanced A9 main board with Linux OS, calculating speed is 4 times faster than traditional products
 
Support storage of 2160 hours trend table and graph review, 2 hours waveform review, 2000 groups NIBP review and 2000 alarm events review
 
Body
12.1 inch high-brightness TFT LED
Support display 9~12 waveforms
Support 7 channel ECG waveform display 
Optional touch screen
 
Printer
Built-in high-speed 50mm thermal printer
 (Brand: SEIKO, Japan) 
 
Central System
Support wired/wireless connection to the central monitoring station. 
 
Alarm
Three-level acousto-optic alarm 
Sensor-off alarm 
Paper out alarm 
Support alarm review 
Support alarm pause
 
 
ECG Full Lead Big Font Display Standard Display
 
OxyCRG Trend Table NIBP Review
OS
Support operation with mouse and computer keyboard (option) 
 
Multi-display mode to meet different clinical requirement, including standard, big font, OxyCRG, trend graph, NIBP review and full leads ECG interface.
 
NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
Generate ID automatically when register a new patient
 
Support medical history search by patient ID, name and mobile number
 
18 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
 
Drug calculation and titration table 
 
Support multi-language display 
Support online software upgrading by net/USB
Interface
Transducer socket
ECG 
SPO2 
NIBP  
IBP 1 / IBP 2
TEMP 1 / TEMP 2 (Mainstream EtCO2) 
 
LAN / Central monitor system interface
The LAN port is for connecting the monitor to a central monitor system network. 
 
Input device interface 
Knob (Standard)
USB interface (optional)
Touch screen (optional)
 
This optional interface provides an USB ports to enable the monitor to be connected to off-the-shelf input devices:
Mouse: any specified trackball or USB mouse may be used for navigation and data entry.
Computer keyboard: an USB computer keyboard can be used for data entry instead of the on-screen pop-up keyboard.
[Remark: user has to restart the machine after plug and unplug the mouse / computer keyboard.]
Knob (Standard)
 
Service Features
The Support Tool helps technical personnel to
–  carry out configuration, upgrades and troubleshooting on an individual monitor.
–back up the monitor settings.
 
The Service Mode is password-protected and ensures that only trained staff can access service tests and tasks. It includes Skin Type, Brightness Setting, Clear Data and NIBP Calibration.
Performance Specifications
 
 
Dimension and Weight
-Dimension: 375mm*330mm*180mm
-Weight: 3.4kg (excluding accessories)
 
Power Supply
-Voltage: AC100~240V, 50/60HZ, 
-Power≤60W
 
Display
-12.1" color TFT LED 
-Resolution: 800*600 pixels
 
Battery 
-Type: Rechargeable lithium battery: 
     12V/2200mAh
-Charge Cycle: ≥500 times
-Working time: 2 hours 
 
Recorder (Option)
-Method: Thermal printer
-Paper width: 50 mm (1.97 in)
-Printing speed: 12.5/ 25/ 50 mm/s
-Trace: Max. 3 tracks
-Recording way: Real-time Recording, Review Printing,  
   Periodic Recording, Alarm Recording
 
Alarm
-Level: Low, medium and high
-Indication: Auditory and visual
-Alarm volume adjustable
-Alarm pause time: 1min, 2min
-Parameter alarm type: Latch/ Unlatch
 
Input Device
-Touch screen (option)
-Knob (Standard)
-Keypad input (Standard)
-Mouse/ Keyboard input (option)
 
System Output & Extensible 
Interface
-Ethernet Network: 1 standard RJ45 socket
 
Safety
-IEC60601-1 Approved, CE marking according to MDD93/42/EEC
-With reference to RoHS Directive 2011/65/EU recasting
 
 
 
Trend & Reviewing
-Trend: 2160 hours
-ARR events: 128 groups of ARR events and associated waveform
-NIBP measurement reviewing: 2000 groups
-Waveform review: 2 hours
Alarm event: 2000 groups of parameter alarms events and associated parameter
 
ECG
-Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
-Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto 
-Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50 mm/s
-ECG signal range:  ±12 mV (Gain × 0.25) Auto
-ECG signal range:  ±6 mV 
-Accuracy: ±1bpm/ ±1%, whichever is greater
-Resolution: 1 bpm
-Leakage Current < 10 μA
-Baseline Recovery: 
 < 5 s after defibrillation (MOR or Surgery mode) 
-Bandwidth: Surgery 1 ~ 20 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
-Indication of Electrode Separation: Every electrode (exclusive of RL)
 
Heart Rate
-Measure range: 
Adult: 0bpm; 15 ~ 300 bpm
Neo/Ped: 0bpm; 15 ~ 350 bpm
-Resolution: 1 bpm
-Accuracy: ± 1% or ± 1bpm, whichever is greater
 
ST Measurement
-Range: -2.0 ~ +2.0 mV
-Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
-Other range: unspecified
-Resolution: 0.01mV
 
Respiration
-Method: Impedance between RA-LL, RA-LA
-Gain: ×0.25, ×0.50, ×1, ×2
-Respiration Rate: Adult: 0 ~ 120 BrPM; 
          Neonatal / Pediatric: 0 ~ 150 BrPM
-Resolution: 1 BrPM
-Accuracy: ±2 bpm or ±2%, whichever is greater
-Apnea Alarm: 10 ~ 40 s
 
 
SpO2 (Analog Technic) 
-Measurement Range: 0 ~ 100 %
-Resolution: 1 %
-Accuracy: 70% ~ 100%: ±2 %  
         40% ~ 69%, ±3 %;
         <39%, unspecified;
 Pulse Rate
-Measuring and Alarm Range: 20~300bpm
-Accuracy: ±3bpm
-Resolution: 1bpm
 
Nellcor-SpO2 (Option)
-Measurement Range: 0 ~ 100 %
-Resolution: 1 %
-Accuracy:   70% ~ 100%, ±2 % (adult)
             70% ~ 100%, ±3 % (Neonate)
             70% ~ 100%, ±2 % (Low Perfusion)
             0% ~ 69%, unspecified
 
Pulse Rate
-Measurement range: 20 ~ 300 bpm
-Resolution: 1bpm
-Accuracy: 
±3 bpm (20 ~ 250 bpm)
Unspecified (251~300 bpm)
 
Masimo-SpO2 (Option)
-- Measurement Range: 0 ~ 100 %
-- Resolution: 1 %
-Accuracy:  
70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions)
70% ~ 100%, ±3 % (neonate, non-motion conditions)
70% ~ 100%, ±3 % (motion conditions)
0% ~ 69% unspecified
 
Pulse Rate
-Measurement range: 25 ~ 240 bpm
-Resolution: 1bpm
-Accuracy: ±3 bpm (non-motion condition)
 
Temperature
-Technique: Thermistor probe (2.25K/10K)
-Channel: Dual-Channel, provide T1; T2; ΔT
-Measuring and Alarm Range: 
0.0 ℃~ 50 ℃ (32℉~ 122℉) 
-Unit: Celsius (℃), Fahrenheit ( ℉)
-Resolution: 0.1℃or 1℉
-Accuracy: ±0.1℃(exclusive probe error)
 
 
Performance Specifications
 
 
NIBP
-Method: Oscillometric
-Measure mode: Manual, Auto, STAT
-STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
-Measure and Alarm Range: 
Adult:       SYS:  40 ~ 280 mmHg
          DIA:  10 ~ 220 mmHg     
          MEAN:  20 ~ 240 mmHg 
Pediatric: SYS:  40 ~ 220 mmHg
DIA:  10 ~ 160 mmHg     
MEAN:  20 ~ 170 mmHg
Neonate:   SYS:  40 ~ 135 mmHg
DIA:  10 ~ 100 mmHg     
MEAN:  20 ~ 110 mmHg
-Static pressure accuracy: ±3mmHg
-Resolution: 1mmHg
-Accuracy: Maximum Mean error ±5mmHg           
         Maximum Standard deviation ≤8mmHg
-Over pressure Protection: Dual protection via software & hardware 
 
 
 
EtCO2 (Mainstream) (Option)
-Measure method:  Non-dispersive infrared (NDIR)
-Measure Range:  0 ~19.7% (0 ~ 150 mmHg)
                 0 ~ 20 kPa
-Resolution: 0.1 mmHg
-CO2 Accuracy:  
0 ~ 40 mmHg, ±2 mmHg
41 ~ 70 mmHg, ±5% of reading
71 ~ 100 mmHg, ±8% of reading
101~ 150 mmHg, ±10% of reading
at 760 mmHg, ambient temperature of 25℃)
-Respiratory Rate:  Range: 3 ~150 BrPM
                Accuracy: ±1 bpm
 
IBP (Option)
-Max Channel: 2
-Measurement way: Thermal resistance way
-Press Sensor:  Sensitivity   5 uV/V/mmHg, ±2%
              Impedance   300 to 3000Ω
-Resolution: 1 mmHg
-Unit: mmKg, kPa
 
 
IBP (Option)
-Transducer sites:  
Arterial Pressure (ART)
Pulmonary Arterial (PA) 
Left
 
Yuesen Med equipment purchase process
Obtenha o preço
Escreva abaixo o seu pedido e entraremos em contacto dentro de 24h!

YOUR MAY ALSO LIKE ...
Monitor de paciente multiparâmetro YSPM80C
Monitor de paciente multiparâmetro YSPM80C
Monitor paciente multiparâmetro YSF8
Monitor paciente multiparâmetro YSF8
YSPM-A12 de monitor paciente multiparâmetro COVID-19
YSPM-A12 de monitor paciente multiparâmetro COVID-19
Oxímetro de pulso pediátrico portátil popular YSDP11