Продукция
Медицинское больничное оборудование многопараметрический монитор пациента YSF9
Предмет №: YSF9
Медицинское больничное оборудование многопараметрический монитор пациента YSF9
Параметры продукта | |
Марка: | YSENMED |
MOQ: | 1 |
Упаковка: | Carton Package |
Время выполнения заказа: | Guangzhou |
Настройка: | 7 days |
ОПИСАНИЕ
Medical hospital equipment Multi-parameter patient monitor YSF9
Features
Core
· Newly advanced A9 main board with Linux OS, calculating speed is 4 times faster than traditional products
· Support storage of 2160 hours trend table and graph review, 2 hours waveform review,
2000 groups NIBP review and 2000 alarm events review
Body
· 15 inch high-brightness TFT LED
· Support display 9~13 waveforms
· Support 7 channel ECG waveform display simultaneously
· Optional HDMI output
Printer
· Built-in high-speed 50mm thermal printer
(Brand: SEIKO, Japan)
Central System
· Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station.
· Optional Support HL7 (Health Level Seven)
Alarm
· Double high light alarm light bar.
· Three-level acousto-optic alarm
· Sensor-off alarm
· Paper out alarm
· Support alarm review
· Support alarm pause
Linux OS
· Support operation with mouse and computer keyboard (option)
· Multi-display mode to meet different clinical requirement, including standard interface, big font, OxyCRG, trend graph, NIBP review and full leads ECG interface.
· NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
· Generate ID automatically when register a new patient
· Support medical history search by patient ID, name and mobile number
· 18 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
· Drug calculation and titration table
· Support multi-language display
· Support online software upgrading by net/USB
Interface
Transducer socket
· ECG
· SPO2
· NIBP
· IBP 1 / IBP 2
· TEMP 1
· TEMP 2 / Mainstream EtCO2 / AG (multi-gas)
· Sidestream EtCO2
LAN / Central monitor system interface
· The LAN port is for connecting the monitor to a central monitor system network.
Input device interface
· This optional interface provides an USB ports to enable the monitor to be connected to off-the-shelf input devices:
· Mouse: any specified trackball or USB mouse may be used for navigation and data entry.
· Computer keyboard: an USB computer keyboard can be used for data entry instead of the on-screen pop-up keyboard.
[Remark: user has to restart the machine after plug and unplug the mouse / computer keyboard.]
· Knob (Standard)
Service Features
· The Support Tool helps technical personnel to
– carry out configuration, upgrades and troubleshooting on an individual monitor.
– back up the monitor settings.
· The Service Mode is password-protected and ensures that only trained staff can access service tests and tasks. It includes Skin Type, Brightness Setting, Clear Data and NIBP Calibration.
· The Support Tool uses the USB interface of the monitor for software upgrading.
Performance Specifications
Dimension and Weight
- Dimension: 393mm*382mm*173mm
- Weight: 4.5kg(excluding accessories)
Power Supply
- Voltage: AC100~240V, 50/60HZ, Power≤60W
Display
- 15" color TFT LED
- Resolution: 1024*768 pixels
Battery (Pluggable)
- Type: Rechargeable lithium battery 14.8V/2200mAh
- Charge Cycle: ≥500 times
- Working time: 2 hours (optional larger battery for 4-5 hours)
Recorder (Option)
- Method: Thermal printer
- Paper width: 50 mm (1.97 in)
- Printing speed: 12.5/ 25/ 50 mm/s
- Trace: Max. 3 tracks
- Recording way: Real-time Recording, Review Printing,
Periodic Recording, Alarm Recording
Alarm
- Level: Low, medium and high
- Indication: Auditory and visual
- Alarm volume adjustable
- Alarm pause time: 1min, 2min
- Parameter alarm type: Latch/ Unlatch
Input Device
- Knob (Standard)
- Keypad input (Standard)
- Mouse/ Keyboard input (option)
System Output & Extensible Interface
- Ethernet Network: 1 standard RJ45 socket
- USB Port: 1
- Video Output: 1 HDMI port (option)
Operating Environment
- Temperature: 5 ~ 40 ℃
- Humidity: 15% ~ 80% (non-condensing)
- Atmosphere pressure: 86 KPa ~ 110 KPa
Transportation and Storage Environment
- Temperature: -20~50 ℃
- Humidity: 10%~90% (non-condensing)
- Atmosphere pressure: 86 KPa ~ 110 KPa
Safety
- IEC60601-1 Approved, CE marking according to MDD93/42/EEC
- With reference to RoHS Directive 2011/65/EU recasting
Trend & Reviewing
- Trend: 2160 hours
- ARR events: 128 groups of ARR events and associated waveform
- NIBP measurement reviewing: 2000 groups
- Waveform review: 2 hours
- Alarm event: 2000 groups of parameter alarms events and associated parameter
ECG
- Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
- Protection: Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof
- Gain: 2.5mm/mV (×0.25), 5.0mm/mV (×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto
- Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
- ECG signal range: ±12 mV (Gain × 0.25)
- Accuracy: ±1bpm/ ±1%, whichever is greater
- Resolution: 1 bpm
- Leakage Current < 10 μA
- Baseline Recovery:
≤ 3s after defibrillation (Monitor mode)
≤ 1s after defibrillation (Surgery mode)
- Bandwidth:Surgery 1 ~ 25 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 120 Hz
- Indication of Electrode Separation: Every electrode (exclusive of RL)
Heart Rate
- Measure range:
Adult: 0bpm; 10 ~ 300 bpm
Neo/Ped: 0bpm; 10 ~ 350 bpm
- Resolution: 1 bpm
- Accuracy: ± 1% or ± 1bpm, whichever is greater
ST Measurement
- Range: -2.0 ~ +2.0 mV
- Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
- Other range: unspecified
- Resolution: 0.01mV
Respiration
- Method: Impedance between RA-LL, RA-LA
- Gain: ×0.25, ×0.50, ×1, ×2, ×4
- Respiration Rate: 0bpm, 6 ~ 150 BrPM
- Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s
- Resolution: 1 BrPM
- Accuracy: ±2 bpm or ±2%, whichever is greater
- Apnea Alarm: 10 ~ 60 s
NIBP
- Method: Oscillometric
- Measure mode: Manual, Auto, STAT
- Measure Interval in AUTO Mode 1~480 min
- STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
- Measure and Alarm Range:
Adult: SYS: 30 ~ 270 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric: SYS: 40 ~ 235 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 225 mmHg
Neonate: SYS: 30 ~ 135 mmHg
DIA: 10 ~ 110 mmHg
MEAN: 20 ~ 125 mmHg
- Static pressure accuracy: ±3mmHg
- Resolution: 1mmHg
- Accuracy: Maximum Mean error ±5mmHg
Maximum Standard deviation ≤8mmHg
- Over pressure Protection: Dual protection via software & hardware
Temperature
- Technique: Thermistor probe (2.25K)
- Channel: Dual-Channel, provide T1; T2; ΔT
- Measuring and Alarm Range:
0.0 ℃~ 50 ℃ (32℉~ 122℉)
- Unit: Celsius (℃), Fahrenheit ( ℉)
- Resolution: 0.1℃or 1℉
- Accuracy: ±0.1℃(exclusive probe)
Performance Specifications
SpO2 (Digital Technic)
- Measurement Range: 0 ~ 100 %
- Resolution: 1 %
- Response Modes: Low, Medium, High
- Accuracy: ±2% (70% ~ 100%)
±3 % (35% ~ 69%)
Unspecified (0 ~ 34%)
- Support Pitch tone and multi-level volume
Pulse Rate
- Measuring and Alarm Range: 25~250bpm
- Accuracy: ±1% or ±1 bpm, whichever is greater
- Resolution: 1bpm
Nellcor-SpO2 (Option)
- Measurement Range: 0 ~ 100 %
- Resolution: 1 %
- Accuracy: 70% ~ 100%, ±2 % (adult)
70% ~ 100%, ±3 % (Neonate)
70% ~ 100%, ±2 % (Low Perfusion)
0% ~ 69%, unspecified
Pulse Rate
- Measurement range: 20 ~ 300 bpm
- Resolution: 1bpm
- Accuracy:
±3 bpm (20 ~ 250 bpm)
unspecified (251~300 bpm)
Masimo SpO2 (Option)
- - Measurement Range: 0 ~ 100 %
- - Resolution: 1 %
- Accuracy:
70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions)
70% ~ 100%, ±3 % (neonate, non-motion conditions)
70% ~ 100%, ±3 % (motion conditions)
0% ~ 69% unspecified
Pulse Rate
- Measurement range: 25 ~ 240 bpm
- Resolution: 1bpm
- Accuracy: ±3 bpm (non-motion condition)
EtCO2 (Mainstream/ Sidestream) (Option)
- Measure method: Non-dispersive infrared (NDIR)
- Measure Range: 0 ~19.7% (0 ~ 150 mmHg)
0 ~ 20 kPa
- Resolution: 0.1 mmHg
- CO2 Accuracy:
0 ~ 40 mmHg, ±2 mmHg
41 ~ 70 mmHg, ±5% of reading
71 ~ 100 mmHg, ±8% of reading
101~ 150 mmHg, ±10% of reading
at 760 mmHg, ambient temperature of 25℃)
- Respiratory Rate: Range: 3 ~150 BrPM
Accuracy: ±1 bpm
EtCO2 (Micro-stream) (Option)
- Measure method: Non-dispersive infrared (NDIR)
- Measure Range: 0 ~19.7% (0 ~150 mmHg)
0 ~ 20 kPa
- Sample Rate: 50 mL/min ±10mL/min
- Resolution: 0.1 mmHg (0 ~ 50 mmHg)
0.25 mmHg (50 ~ 114 mmHg)
- CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg
41 ~ 70 mmHg, ±5% of reading
71 ~ 100 mmHg, ±8% of reading
101~ 150 mmHg, ±10% of reading
at 760 mmHg, ambient temperature of 35℃)
- Respiratory Rate: Range: 3 ~120 BrPM
Accuracy: ±1 bpm
Depth of Anesthesia (CSI) (Option)
- EEG sensitivity: ± 400μV
- Noise: < 2μVp-p, < 0.4μV RMS, 1-250 Hz
- CMRR: > 140 dB
- Input impedance: > 50 Mohm
- Sample rate: 2000 samples/sec, (14 bits equivalent)
- BS%: 0-100, filter 1-42 Hz, 1 sec. display update
- EMG: 0-100 Logarithmic. Filter 75-85 Hz, 1 sec. update
- Alarms: High / Low with user selectable limit
- Artifact rejection: Automatic
- Sensor impedance range: 0 - 10 kOhm / measurement current 0.01 μA
Multi-gas/O2 (Anesthetic Gas) (Option)
- Method: Infrared absorption
- Gas sorts: CO2, N2O, Des, Iso, Enf, Sevo, Hal,
O2 (Optional paramagnetic sensor)
- Calibration: Room air calibration performed automatically when changing airway
Airway adapt (< 5 sec)
- Measurement range:
CO2: 0~25%, N2O : 0~100%
O2: 0~100%, Enf, Iso, Hal: 0~25%,
Sevo, Des: 0~25%
- Data output: Fi and ET values
- Respiration rate: 0~ 150 BrPM
- Other: Up to 5 waveforms displayed
Agent mixture detection
MAC value displayed
IBP (Option)
- Max Channel: 2
- Measurement way: Thermal resistance way
- Press Sensor: Sensitivity 5 uV/V/mmHg, ±2%
Impedance 300 to 3000Ω
- Resolution: 1 mmHg
- Unit: mmKg, kPa, cmH2O
- Transducer sites:
Arterial Pressure (ART)
Pulmonary Arterial (PA)
Left Arterial (LAP)
Right Arterial (RAP)
Central Venous Pressure (CVP)
Intracranial Pressure (ICP)
P1/ P2
- Measuring and alarm range:
ART 0 ~ +350mmHg
PA -10 ~ +120 mmHg
CVP/ RAP/ LAP/ ICP-10 ~ +40 mmHg
P1/ P2-50 ~ +350mmHg
- Accuracy:
Static: ±1mmHg or ±2%, whichever is greater (exclusive of transducer)
±4mmHg or ±4%, whichever is greater (inclusive of transducer)
Dynamic: ±4mmHg or ±4%, whichever is greater
The YSF9 patient monitor is designed to match the pace and unique needs of adult, pediatric,
and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments.
An optional USB Mouse/Keyboard control eases navigation and data entry.
An optional HDMI output eases observation from a long distance.
and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments.
An optional USB Mouse/Keyboard control eases navigation and data entry.
An optional HDMI output eases observation from a long distance.
YOUR MAY ALSO LIKE ...